Loading...
 

Synchronize Deleted Raw Data Soundings Between Software Channels

The Synchronize deleted Raw Data soundings Between Software Channels form offers a quick way of using the manual processing of one software channel to delete soundings from the other. Is is available from the Commands menu of the AEM Edit Form (EditFormAEM).

The available settings are:

  • Software channel with deleted soundings (source): Here you select which software channel is the source for the deletion.
     
  • Software channel to delete soundings from (target): Here you select which software channel is the target for the deletion.
     

Delete Soundings buffer width: Here you select how many additional soundings (in time) to delete. Example. If soundings from time interval 17:31:23 to 17:32:16 has been deleted from the source software channel and Delete Soundings buffer width is 2 seconds all soundings from time interval 17:31:21 to 17:32:18 will be deleted from the target software channel.